Operating Instructions SATAminijet 3000 B HVLP, minijet 3000 B T HVLP
US
Malfunction
Corrosion on air cap
thread, inside material
passages (cup con-
nection) or on spray
gun body
Material leaks from be-
hind the paint needle
sealing
Spray gun leaks from
the fluid tip ("fluid tip
aperture")
11. Disposal
Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!
12. After Sale Service
For accessories, spare parts and technical support, please contact your
SATA dealer.
13. Warranty / Liability
The SATA General Conditions of Sale and Delivery and further contractual
agreements, if applicable, as well as the valid legislation at the time apply.
SATA cannot be held responsible especially in the following
cases:
• When the operating instructions are disregarded
• When the product is used in other than the intended ways of usage.
• When untrained staff is employed.
414
Cause
Cleaning solution
(water-based) remains
inside/on the spray
gun for too long
Unsuitable cleaning
media
Defective or missing
paint needle sealing
Clogged or damaged
paint needle
Contamination be-
tween paint needle tip
and fluid tip
Damaged nozzle set
Corrective action
Cleaning, observe
chapter 8, get a re-
placement spray gun
body.
Replace / insert paint
needle sealing, chap-
ter 9.3
Replace nozzle set,
chapter 9.1; replace
paint needle sealing, if
necessary, chapter 9.3
Clean fluid tip and
paint needle, observe
chapter 8
Replace nozzle set,
chapter 9