The high-pressure cleaner is supplied with five
different nozzle types:
- Low-pressure nozzle (fig. 3A, "CHEMICAL"): for
operating with detergent or cleaning with negligible
pressure,
- 0° nozzle: straight stream (fig. 3B) for particularly
stubborn accumulation of grime,
- 15° nozzle: flat spray (fig. 3C) for dirt accumulation
over a large surface,
- 25° nozzle: flat spray (fig. 3D) for dirt accumulation
over a large surface,
- 40° nozzle: flat spray (fig. 3E) for dirt accumulation
over a large surface.
fig. 3A fig. 3B fig. 3C
IV. APPLIANCES PROVIDED WITH THERMAL VALVE
This device enables the machine's by-pass operation
through automatic water discharge whenever it reaches
a temperature of nearly 60°C and cooling working
components.
CAUTION: appliances that are not provided with
this disposal must not operate for more than 2
minutes with released gun. Recycled water raises its
temperature remarkably causing great damages to the
pump.
MONTAGE
Study the series of photos shown below (fig.4):
OPERATING INSTRUCTIONS
CAUTION! Do not run the engine with a high or low
oil level as this can cause engine damage. If you have
further questions regarding the engine, please refer to
the engine's operating manual included with the unit.
2x
fig. 4
CAUTION! The engine is not provide with oil. It is
necessary to fil the carter before starting the engine.
CAUTION! Before starting the pump, check the oil
level in the pump.
CAUTION! If it is the first time that you use the
machine or if you do not operate the machine for a long
period, it is necessary to connect, for some minutes, the
suction hose, in order to let possible impurities go out,
so that the nozzle gun will not become clogged.
CAUTION! Fill gas tank with unleaded gasoline. Do
not use leaded gasoline.
I. STARTING UP

WATER SUPPLY

fig. 3D
fig. 3E
mation
CAUTION:
preventers is considered to be nonpotable.
Caution - Danger!
Only clean or filtered water should be used for intake.
The water intake should be at least twice the pump ca-
pacity.
-
-
-
Place the cleaner as close as possible to the water sup-
ply.
Water supply from the water main
WARNING: (symbol) machine not suitable
for connection to the potable water mains.
Water that has flown through backflow
Minimum delivery rate: 15 l/min
Maximum intake water temperature: 40°C
Max inlet water pressure: 1Mpa
inlet of the unit and to the water supply.
-
4x
15