Power requirements Part 1
General
The points below describe the power requirements for the use of the
isoweld
induction machine. These notes are recommendations.
®
Each job site and its power situation is individual and therefore no
performance guarantee can be given.
In addition to the recommendations stated in this document, the local
safety and electrical regulations applicable in the country of use must be
observed.
Consultation of a qualified electrician is advisable.
Electrical safety
Connect the machine to a socket with a protective ground conductor
Any breakage/disconnection of the protective conductor inside or
outside the tool is potentially dangerous! Use only extension
cables with an ground conductor!
When the tool is used on building sites, the use of an RCD switch is a
mandatory requirement for personal protection.
Power supply
Stable power is essential for problem-free operation of the induction
machine.
A minimum of
- 20 amps per electrical circuit required for countries with 110 volts /
120 volts nominal voltage
- 10 amps per electrical circuit required for countries with 230 volts
nominal voltage
Maximum one induction machine per circuit, with a recommendation
not to use other devices on the same circuit as the isoweld
isoweld
Backpack.
®
Off-load voltage shall not exceed:
- 160 volts for countries with 110 volts / 120 volts nominal voltage
- 240 volts for countries with 230 volts nominal voltage
On-load voltage at the point of utilization at the machine terminals, with
the machine running, must be higher than:
- 110 volts for countries with 110 volts / 120 volts nominal voltage
- 200 volts for countries with 230 volts nominal voltage
It is preferable for the induction machine to have its own dedicated
power supply so as to avoid power surges from other equipment, e.g.
drill machines.
Generator
Use a minimum 5000 watt generator
Requirements volts and amps see above
With ground fault circuit interrupter (GFCI)
Grounding / earthing required
Transformer
Necessary for use in countries with a nominal voltage of 110 volts if the
voltage at the point of utilization, with the machine running, falls below
110 volts.
The functionality of the system is only ensured if the transformer
provided by SFS is used.