Step 2: Installing the new generator into the frame
Remove the 4 T20 screws from the new frame (left) and pull the grey shell off
(right).
Pop the orange shell of the studs by pushing against the frame while pulling the
shell in the direction shown (left). Do this for all 4 studs (two on each side).
Lift up on the orange shell pulling from the point shown (left). The tab on the
orange shell that slides inside the frame might be a tight fit so if it does not
easily slide out, try to pry between the frame and the shell. Three inches should
be enough clearance to get the generator in.