Error messages
Error message Cause
Error 01
voltage problem
Error 02
overload
Error 03
system error
Error 04
system too hot
Error 05
welding not
complete
Error 06
no plate
Error 07
plate lost
Error 08
temperature
sensor
Error 09
no calibration
Error 10
mains voltage
Voltage supply is too low for
the tool
Max. permitted inductor current
exceeded
System error
Tool has heated up too much
Required welding temperature
not reached
Max. search time exceeded
Inductor has been accidental-
ly moved during the welding
process
Temperature sensor defective
The program used has not been
calibrated
Permissible input voltage too
low
Action
Press the
button.
OK
•
Choose an electricity circuit
with less load
•
Reduce the length of the
supply cable
•
Change the supply voltage to
230 V (GB, USA, CAN).
Press the
button.
OK
•
Restart the welding process
•
Should this error message be
displayed repeatedly, please
contact your SFS service
provider.
Press the
button.
OK
•
Restart the welding process
•
Should this error message be
displayed repeatedly, please
contact your SFS service
provider.
Press the
button.
OK
Turn off the tool at the main switch
and allow to cool down.
Press the
button.
OK
Allow the weld point to cool down
and restart welding process.
Press the
button.
OK
•
Check that there is a stress
plate
•
Allow the weld point to cool
down and restart welding
process.
•
Should this error message
be displayed several times,
recalibrate the tool.
Press the
button.
OK
Allow the weld point to cool down
and restart welding process.
Press the
button.
OK
Contact your SFS service provider.
Press the
button.
OK
Calibrate the tool in accordance
with the "Calibration" section.
Press the
button.
OK
•
Choose an electricity circuit with
less load
•
Reduce the length of the supply
cable
•
Change the supply voltage to
230 V (GB, USA, CAN).
27