EN-30
4.12.1 Manual Display Hold (dHMAn) (Cont.)
When a load exceeding 5d (divisions) above zero is placed on the scale, the
highest stable weight reading will be frozen on the display and the cursor will
stop blinking. Example 5kg.
If an additional load exceeding 5d above the current Display Hold value is
added to the scale (example 10kg), the value will be replaced by the new
Display Hold value.
A short press of the PRINT/ Units button sends the Display Hold value to the
RS232, the display is unfrozen, the scale returns to the normal weighing mode
and the Display Hold cursor turns off. The Display Hold value can also be
cleared, without sending the value to the RS232, by turning the scale off.
4.12.2 Semi-automatic Display Hold (dHSEM)
When dHSEM is selected, the Semi-Automatic Display Hold mode becomes
active immediately upon exiting the SEtuP menu. In this case, the display hold
operation starts automatically and is cleared manually.
When a load exceeding 5d above zero is placed on the platform, the highest
stable weight reading will be frozen on the display and the cursor will stop
blinking. Example 5kg.
If an additional load exceeding 5d above the current Display Hold value is
added to the scale (example 10kg), the value will be replaced by the new
Display Hold value.
After the load is removed to within 5d of zero, a short press of the PRINT/ Units
button sends the Display Hold value to the RS232, the display is unfrozen, the
scale returns to the ready mode and the Display Hold cursor resumes blinking.
The Display Hold value can also be cleared, without sending the value to the
RS232, by turning the scale off.
CD-11 Indicator
Display
Gross
Stable
Brutto
Hold
Gross
Stable
Display
Brutto
Hold
Stable
Gross
Brutto
> 0 <
> 0 <
> 0 <
> 0 <
> 0 <
Gross
Stable
Display
Brutto
Hold
Display
Gross
Stable
Brutto
Hold
Stable
Display
Gross
Brutto
Hold
Stable
Display
Gross
Brutto
Hold