7.2.4 ALARM DISPLAY FOR THE OIL TO BE REPLACED VGP25N.
BLOCkED FUNCTIONS DUE TO THE OIL HAVING FINISHED.
Once the maximum admissable number of 10.000 cycles has been reached, at each start-up and at the end of every cycle,
the LEDs start to flash, which means that the oil must be replaced. The alarm is reset once the oil is replaced.
ATTENTION! If the oil change alarm has been triggered, contact your authorised after-sales centre for it
to be replaced.
WARNING! The indication protects the pump from rapid deterioration due to oxidation and maintains the
machine's maximum efficiency and performance.
A safety device will stop the pump when the oil drops below the set limit in order to prevent irreparable damage.
7.2.5 ALARM DISPLAY OF VGP25N PUMP OVERHEATING
If a fault occurs in the the vacuum pump, the machine stops the cycle and the LEDs flash at regular 3-second intervals.
"WARNING - OVERHEATING" appears on the display.
The machine does not accept commands in such conditions.
ATTENTION! If pump overheating alarm is triggered, switch the machine off and wait for about 15 minutes
until it cools down.If the alarm persists once the machine is switched on again, switch the machine off
and disconnect it from the mains. Contact your authorised after-sales centre.
7.3 LOCATION OF THE PROGRAMS VGP25N
Choose the desired program by using the "UP" and "DOWN" cursor keys.
The table below lists the types of programs available and where they are located.
POSITION
1° - 20°
21°
7.3.1 NAMING CUSTOM USER PROGRAM VGP25N
It's possible to assign to each user program (1 - 20) a name, consisting of up to 6 letters.
Proceed as follows:
PHASE DESCRIPTION
1
Select one of the 20 programs available.
2
Enter programming by keeping "PROG" button pressed for 4 seconds (the first
digit of the lower display starts to flash).
3
Select a letter.
4
Confirm the letter and access the next to be programmed.
5
Confirm.
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
PROGRAM NAME
USER 1 - 20
ONLY SEALING
OPERATION VGP25N
PROGRAM TYPE
VACUUM - GAS PROGRAMS
ONLY SEALING PROGRAMS
kEY