OPERATION VGP25N
7.4 PROGRAMMING AND OPERATION VGP25N
7.4.1 PROGRAMMING VGP25N
PHASE DESCRIPTION
1
Select one of the 20 programs available.
2
Select the function to be programmed (vacuum – gas – sealing).
3
Enter programming (the bright icone of the function starts to flash).
4
Change the value.
5
Confirm the value or access the next function to be programmed by pressing
the "SEL" button.
6
Proceed with other functions to be changed and each time confirm with the
"PROG" button.
7.4.2 VACUUM - GAS FUNCTION ON VGP25N
1) Check to make sure the temperature regulator indicates the
maximum programmed temperature; this value is usually
reached after about 10 minutes.
2) Programming it as described above.
3) Fit the insertion plates according to the size of the containers.
4) Insert container
A
containing the product in the tray die.
5) Start up the pump.
6) Stretch film
B
on the container and block it by means of three suction cups
7) Lower head
D
by pressing slightly initially; the machine carries out the packaging cycle according o the programmed
parameters. At the end of the cycle, the sealing head opens automatically.
8) Eliminate the film waste, remove the packed product and proceed with a new cycle.
B
32
A
C
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
C
.
D
kEY