Changing The Fuses; Replacing The Fuses - Orved N Serie Manual De Uso

Termosoldadora de cubetas en atmósfera modificada
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ROUTINE MAINTENANCE
8) Remove the solenoid valve block complete with filter and insert the new unit.
9) Fix the new block to the insertion plate by means of two screws and proceed with connecting the six Ø 9 tubes in the
positions marked earlier.
10) Reconnect the electrical connections described at point 7).
11) Connect the two spiralled tubes described at point 3) to the hose connector unions on the pump side and tank side.
12) Before refitting the rear panel, carry out a complete work cycle to make sure that the machine works correctly, by
connecting it to the electricity mains and ensuring that the body parts cannot come into contact with the powered
parts of the machine.
13) Refit the rear panel by tightening the 10 fixing screws using a No. 2 T male hex wrench.
VGP25N

10.12 CHANGING THE FUSES

VALUES OF FUSES PF1-PF4 AMPERES
POSITION
MODEL
VGP25
FUNCTION
PUMP
PROTECTION
VALUE (A)
10
PF1
PF2
52
PF1
VGP60
VGP25
SEALING
PROTECTION
12
8
PF3
VGP60N
PF2
VGP60
VGP25
100VA AUxILIARY
PLATE
TRANSFORMER
POWER SUPPLY
-
1
PF4
PF1
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
PF3
VGP60
VGP25
PROTECTION
-
5
PF4
VGP60
BOARD
-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vgp25nVgp60n

Tabla de contenido