9.2 SCHEDULED ROUTINE MAINTENANCE

FREQUENCY
Before each start-up
Weekly
Every 10000 work cycles
Every 150000 work cycles
Every other oil change
Every 1000 operating hours
Every 6 months and after ha-
ving been idle for a long time
Every 2 months
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
CONTROL, CLEANING, SANITIZATION OF MACHINE
MACHINE PART
Pump
Power cable
Tray neoprene gasket
Sealing plate
Machine and Vacuum chamber
Sealing bar connection
Tank filter
Pump
Machine, vacuum chamber, lid and
panels
VGP25N
VGP60N
Pump.
VGP60N
Pump.
Suction cup filters
INTERVENTION
Check the level and colour of the oil; top-up or
replace, if the colour is too dark or whitish.
Verify its integrity; replace if defective (contact
a specialised after-sales centre).
Check to make sure these are inserted correctly
in their seats; replace if defective.
Check to make sure it is clean and free of impu-
rities and encrustations.
Clean impurities, oil and grease.
Check that it is inserted well on to the two
contact pins.
Check to make sure it is empty and free of
impurities.
Run the pump for about 5 minutes (by means of
the pump key) to allow removal of water from
the pump oil.
Disinfect
Replace the pump oil
(contact a specialised after-sales centre).
Replace the pump purifier filter (contact a spe-
cialised after-sales centre).
Replace the oil filter (contact a specialised after-
sales centre).
Replace the pump oil (contact a specialised
after-sales centre).
Clean and dry the suction cup filter.