27
AL-B-27
33
AL-W-01
34
AL-W-02
35
AL-W-03
36
AL-W-04
37
AL-W-05
38
AL-W-06
39
AL-W-07
40
AL-W-08
41
AL-W-09
42
AL-W-10
43
AL-W-11
44
AL-W-12
49
AL.M1
50
AL.M2
51
AL.M3
52
AL.M4
53
AL.M5
54
AL.M6
Record
Record type is used in comunication record to contain single alarm event or for an analogic measure.
Data has a dual interpretation in case it refers to an alarm or to a measure but occupancy is in any case the maximum one, 18byte.
The two possible forms are the following.
In case of a measure bytes, in receiving order, have to be interpreted as follows:
0 - DAY OF MONTH (1..31)
1 - MONTH (1..12)
2 - YEAR (0..99, 0=2000)
3 - HOURS (0..23)
4 - MINUTES (0..59)
5 - TYPE (0, 2, 3, 4)
6 - PRESSURE P1 [mbar] Least Significant Byte (LSB)
7 - PRESSURE P1 [mbar] Most Significant Byte (MSB)
8 - PRESSURE P2 [bar*100] LSB
9 - PRESSURE P2 [bar*100] MSB
10 - PRESSURE P3 [bar*10] LSB
11 - PRESSURE P3 [bar*10] MSB
12 - TEMPERATURE T2 [°C*10] LSB
13 - TEMPERATURE T2 [°C*10] MSB
14 - TEMPERATURE T3 [°C*10] LSB
15 - TEMPERATURE T3 [°C*10] MSB
16 - TEMPERATURE T4 [°C*10] LSB
17 - TEMPERATURE T4 [°C*10] MSB
In case of an alarm, in receiving order, have to be interpreted as follows:
0 - DAY OF MONTH (1..31)
1 - MONTH (1..12)
2 - YEAR (0..99, 0=2000)
3 - HOURS (0..23)
4 - MINUTES (0..59)
5 - TYPE (1)
6 - ALRMCODE
ALRMCODE data is coded as per preceeding tab.
Remaining 11 bytes have to be ignored.
In both cases first 6 bytes have same meaning. Byte TYPE permits to differentiate the format of the following bytes:
TYPE=0 refers to a record of analogic measures periodically recorded (code M for record in "Serial Connection" paragraph)
TYPE=1 refers to a record of an alarm type (code A for record in "Serial Connection" paragraph)
TYPE=2 refers to a record of measures recorded at the Run command of the unit (code R for record in "Serial Connection" paragraph)
TYPE=3 refers to a record of measures recorded at the Stop command of the unit (code S for record in "Serial Connection" paragraph)
TYPE=4 refers to a record of measures recorded at the execution of Autotuning operation (code T for record in "Serial Connection" paragraph)
60
W3-0A5 12-I
Transm. Belt broken
Set data lost
RS232 connection fault
RS485 connection fault
Rpm pre alarm
P1 Pre alarm
P2 Pre alarm
T2 Pre alarm
T3 Pre alarm
T4 Pre alarm
Internal clock fault
Rpm sensor fault
Wrong rotation direction
Count down 6-M1-expired
Count down 6-M2-expired
Count down 6-M3-expired
Count down 6-M4-expired
Count down 6-M5-expired
Count down 6-M6-expired