Migatronic PI 200 DC HP Manual De Instrucciones página 19

Ocultar thumbs Ver también para PI 200 DC HP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
4-times option for torch trigger
Permit to define 6 different ways to
control the torch trigger when the machine is set
as 4Times stroke (Lift or HF). Mode 3 is called
4T-REPEAT and permits to keep the arc active
also at the end of slope down for an easier restart
of sequence. In Mode 3 the function "Second
current level" is disabled. For detailed description
of different behaviours see the following
diagrams. Select a value in the range 0...5
(1=default setting).
Note: The start current is disabled in
if slope-up period is set at 0.
Dynamic Oxide Control
(for AC welding).
0 = disabled
1 = enabled (default setting)
All above settings are not modified via Reset.
,
and
19
Torch Remote Control
Applies to software versions as of 1.10
Makes it possible to control how the control unit
on the handle is used when torch adjustment is
enabled (
).
0 = Setting the current reference (factory
default).
1 = Enabling/disabling TIG-A-Tack
(the TIG-A-Tack button is disabled).
The control unit is handled as follows:
Steps 1-3: TIG-A-Tack is
enabled
Steps 4-7: The trigger is
disabled
Steps 8-10: TIG-A-Tack is
disabled
2 = Up/Down module
Trigger
Enabling/Disabling
TIG-A-Tack
* Keep pressed for
constant increase/reduction
Learn more about TIG Ergo torches at
http://migatronic.com
Trigger

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pi 250 dc hpPi 200 ac/dc hpPi 250 ac/dc hp

Tabla de contenido