requirements for the operation of automatic doors and gates. In particular, these
standards require the use of force limiting and safety devices (sensing ground
plates, photocell barriers, hold-to-run operation, etc.) intended to detect persons or
objects in the operating area and prevent collisions in all circumstances.
The installer is required to measure impact forces and select on the control unit the
appropriate speed and torque values to ensure that the door or gate remains within
the limits defined by the standards EN 12453 and EN 12445.
ROGER TECHNOLOGY cannot be held responsible for any damage or injury caused
by the installation of incompatible components which compromise the safety and
correct operation of the device.
If the hold-to-run function is active, the installer will have the obligation to check
the maximum stop distance or the alternative use of the rubber deformable edge,
the closing speed or the gate and in general all aspects indicated by the applicable
regulations. Moreover, please not that if the command means is fixed, it must be
located in a position guaranteeing the automation system control and operation and
the command type and the use type must comply with the UNI EN 12453 standard,
prospectus 1 (with the following restrictions: type A or B command or type 1 or 2
use).
In case of hold-to-run operation, remove any potential persons away from the range
of action of the automation system's moving parts; the direct commands must be
installed at a minimum height of 1.5 m and must not be accessible to the public;
moreover, unless the device is key operated, they must be located with a direct view
to the motorised part and far from the moving parts.
Apply the signs indicated by the regulations in force for the identification of the
dangerous areas.
Each installed device must have a visible indication of the motorised door or
gate identification data, in accordance with the EN 13241-1:2001 standard or
subsequent revisions
A switch or an omnipolar cut-off switch with a contact opening of at least 3
mm must be installed on the mains power line; put the cut-off switch in OFF
position and disconnect any buffer batteries before performing any cleaning or
maintenance operations.
Ensure that an adequate residual current circuit breaker with a 0.03 A threshold
and a suitable overcurrent cut-out are installed upstream the electrical installation
in accordance with best practices and in compliance with applicable legislation.
When requested, connect the automation to an effective earthing system that
complies with current safety standards.
The electronic parts must be handled using anti-static conductive wrist straps with
grounding wire.
Only use original spare parts when repairing or replacing products.
The installer must provide the user with complete instruction for using the motorised
door or gate in automatic, manual and emergency modes, and must hand the
operating instructions to the user of the installation upon completion.
Keep away from hinges and moving parts.
Keep out of the area of action of the motorised door or gate while it is moving.
59