PROBLEM
ALARM SIGNAL
Acquisition proce-
dure does not com-
plete correctly.
Barrier does not
perform desired
manoeuvre.
The barrier opens/
closes for a short
distance and then
stops.
The remote control
has limited range
and does not work
with the automation
moving.
The flashing light is
not working.
Barrier open indi-
cator lamp does
not work.
N.B.: Press the TEST button to temporarily cancel the alarm.
The next time a command is received, the alarm reappears on the display if the problem has not been resolved.
POSSIBLE CAUSE
Motor calibration failed.
TEST button pressed accidentally. Repeat acquisition procedure.
Safety devices in alarm state.
Excessive voltage drop.
Incorrect setting of parameter
Incorrect setting of parameter
Incorrect values for installation
type.
Incorrect spring setting.
Battery operation management
(par.
different than
) not
detected.
Radio signals are impeded by
metal structures and reinforced
concrete walls.
Flat batteries.
Bulb / LED blown or flashing light
wires disconnected.
Bulb blown or wires disconnected. Check the bulb and/or wires.
CORRECTIVE ACTION
Repeat acquisition procedure.
If the problem persists, check the cable connecting
encoder 1 to the motor.
Check that the motor turns without impediment. Contact
technical support in case of any problems.
Check connections of safety devices.
Repeat acquisition procedure; check mains voltage.
. Select the correct installation position with parameter
. Repeat acquisition procedure.
. Check type of boom and set parameter
Repeat acquisition procedure.
Set values of parameters
,
for installation type.
See the barrier instructions for spring balancing.
Change the value of the parameter
Install the antenna.
Replace the radio control batteries.
Check LED circuit and/or connector wires.
correctly.
,
and
correctly
.