9.3 Technical specifications
Diameter of wire workable
Speed of wire feed
Power of geared motor
Wire feed button
Gas discharge button
Remote control
Connector for Push-Pull torch
Steel rollers
Teflon rollers
Protection rating
Insulation class
Weight
Dimensions (HxWxD)
Data at 40°C ambient temperature
10.0 INSTALLATION
Details of the mobile trolley
Fig. 21
a) Connect the cable bundle to the socket D2 / J3 (fig. 20) and
the pipes of the cooling liquid, if used, to the sockets A3 / A4.
b) Connect the gas pipe to the ¼" rear fitting (fig. 24).
c) Open the trolley mobile bonnet, exerting pressure on the
two slide fastenings, and remove any accessory elements
provided in the compartment.
d) Check that the roller groove coincides with the diameter of
the wire you wish to use.
e) Unscrew the ring nut (G1 fig. 21) from the coil reel and insert
the coil.
Fit the reel metal pin into its housing, replace the ring nut
(G1) and adjust the friction screw (G2 fig. 21).
26
WF104
0.8-1.0/1.2-1.6
0.8-1.0/1.2-1.6 aluminium
1.0-1.2-1.4-1.6 cored
1-22 m/min.
120W
yes
yes
optional
optional
yes
yes
IP23S
H
18 Kg.
435x220x600 mm
f) Release the feed support of the gearmotor (M1 fig. 21), slid-
ing the end of the wire into the wire guide bush and, passing
it over the roller, into the torch fitting.
Lock the feed support (M1) in position, checking that the
wire has entered the roller groove.
g) Insert the torch, complete with sheath, into the central fitting
(C1 fig. 21), fully tightening the ring nut. If the torch is water-
cooled, connect the delivery and return pipes to the cou-
plings (A5-A6 fig. 19).
If the pipe bundle cooling liquid pipes are connected and the
torch is not liquid-cooled, see 5.1.2.
Switch the power source on only after checking correct tight-
ening of connectors and quick-fit couplings.
11.0 POSSIBLE PROBLEMS
The problems that arise in welding can have electrical or
mechanical origins or can be due to an incorrect use of
the apparatus. The problems relating to welding are
described in the operator's manual the generator.
FAULTS
The wire does not feed
The wire feeds but the arc
does not strike
12.0 ACCESSORY KIT
COMPOSITION
Accessory kit for wire-feeding trolley, 4 rollers
Wire-tightner roller, lower, 120W, 1.6-AN
Spray, non-stick, non-silicone, 500g
Accessory kit, aluminium, for wire-fedding
trolley, 4 rollers
Teflon roller, 120W, 1.2-1.6
Teflon wire guide, bush, 120W
CAUSA
a) line fuse blown,
b) fuse on generator blown,
c) torch switch faulty,
d) cable bundle defective,
e) rollers worn,
f) torch nozzle melted (wire
stuck),
g) generator alarm triggered,
h) soft start on and value set to
minimum.
a) earth return clamp is not
making contact with the
piece to be welded,
b) incorrect selection and set
up of welding para-meters,
c) positive cable (cable undle)
disconnected,
d) fault in generator (contact
the SELCO Service Dept ).
CODE
73.10.002
73.10.029