GF 4, GF 6, RA 8, RA 12 (AVM/MVM)
9.1
Processing the pipe with AVM
For more information on pipe processing with MVM, see from chap. 9.2, page 92.
For manual operation without AVM or MVM, see from chap. 9.3, page 95.
IMPORTAnT!
9.1.1
Shutting down (even in an emergency)
DAnGeR!
IMPORTAnT!
12
X Activate by switching the ON/OFF toggle switch (13). If the ON/OFF toggle switch (13) fails to work, remove the plug from the
socket or vacate the danger zone as quickly as possible and then remove the plug.
9.1.2
Initial operation
1. Connect the pipe cutter with swivel cable to the AVM.
2. Connect the mains cable of the AVM to the main power supply.
[REV. 20190510] OC_GF_RA_BA_790142765_00__INH-02_EN
Only operate AVM in combination with the Orbitalum Tools pipe cutters GF 4, GF 6, RA 8 or RA 12.
X Do not connect any other devices to the socket of the AVM.
eMeRGency STOP function not available by unplugging the power plug!
Diverse physical injuries and material damage.
X Do not use angled power plugs.
X Do not use click-in socket outlets and click-in power plugs (blue CEE power plugs) for
power connection, otherwise the EMERGENCY STOP does not function. The user must
check whether the power plug can be pulled out of the outlet by the cable.
X Only use original Orbitalum Tools parts.
X Ensure free access to the power plug.
X A radial space requirement/freedom of movement of approx. 2 m around the machine is
required for people.
EMERGENCY STOP button (12) on the AVM:
Only press in an emergency. Pressing the EMERGENCY STOP button (13) interrupts the
power supply. Unlock the button to restart.
Operation
Orbitalum Tools GmbH D-78224 Singen www.orbitalum.com
enGLISH
13
89