Removing The Apparatus - MSA AirHawk II Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REMOVING THE APPARATUS

DISCONNECTING THE PUSH-TO-CONNECT
REGULATOR
1. Grasp top of regulator.
2. Push the release
buttons and pull
regulator down and out
of facepiece adapter.
3. Close the cylinder valve
fully. Open the bypass
to release system
pressure. Close the
bypass.
4. Stow the regulator with
red bypass knob
pointing to the right in
the STAND-BY belt
mount.
5. To remove the facepiece, fully loosen the harness
straps and pull the facepiece up and away from your
face.
6. To remove the carrier harness, press the belt buckle
release buttons IN.
TAL 1211 (L) Rev. 4 - 10088650
REMOVING THE APPARATUS
10
7. Disconnect the chest strap (if used).
8. To loosen the shoulder straps, grasp the release tabs.
Push them out and away from your body.
9. Slip your right arm out of the shoulder strap first, then
remove the harness.
Note: Be sure to replace the cylinder with a full one.
Complete Inspection and Cleaning and Disinfecting
Procedures are outlined in this manual. Ensure complete
apparatus is clean and dry. Ensure that facepiece head
harness straps and harness adjustment straps are fully
extended. Place the complete apparatus in the storage
case or suitable storage location so it can be reached
easily for emergency use. (See storage instructions.)
DISCONNECTING THE SLIDE REGULATOR
1. Grasp top of regulator.
2. Push the release buttons and pull regulator down and
out of facepiece adapter.
Note: Regulator can hang on cover rail in a stand-by mode.
3. Slide regulator up rail until regulator slide button is
free of cover rail.
4. Close the cylinder valve fully. Open the bypass to
release system pressure. Close the bypass.
5. Stow the regulator with red bypass knob pointing to
the right in the STAND-BY belt mount.
6. To remove the facepiece, fully loosen harness straps
and pull the facepiece up and away from your face.
7. To remove the carrier harness, press the belt buckle
release button IN.
8. Disconnect the chest strap (if used).
9. To loosen the shoulder straps, grasp the release tabs.
Push them out and away from your body.
10. Slip your right arm out of the shoulder pad first, then
remove the harness.
Note: Be sure to replace the cylinder with a full one.
Complete Inspection and Cleaning and Disinfecting
Procedures are outlined in this manual. Ensure complete
apparatus is clean and dry. Ensure that facepiece head
harness straps and harness adjustment straps are fully
extended. Place the complete apparatus in the storage
case or suitable storage location so it can be reached
easily for emergency use. (See storage instructions.)
CHANGING THE CYLINDER WITH BAND AND LATCH
Be careful not to drop cylinder or bump valve knob. An
unsecured cylinder can become an airborne projectile
under its own pressure if the valve is opened even
slightly. Failure to follow this warning can result in
serious personal injury or death.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Air mask

Tabla de contenido