Database Function; Creating A Data Record - Data Function - Gossen MetraWatt GEOHM C Manual De Instrucciones

Ocultar thumbs Ver también para GEOHM C:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 174
6

Database Function

Displayed measurement data can be saved individually for each measure-
ment to the internal database either with or without a comment. In order
to assign the individual measured values to various buildings, customers
etc., a data record must first be created with its own memory address.
6.1
Creating a Data Record – Data Function
Ð
Press the data softkey.
Ð
First, enter the desired memory address with the softkeys. After
acknowledging this entry with the START key (press at center), the
cursor appears at the first entry position (BUILDING).
No entry is required for the customer ID field, as long as measurements
are only performed for a single company.
The M-TYPE field (measurement type) is used to designate what kind of
measurement is involved. This entry is required in order to generate a
report with PS3 test instrument software for lightning protection systems.
GMC-I Messtechnik GmbH
M-TYPE Setting
Significance
D
Continuity to metallic installations
DG
Continuity to metallic gas lines
DW
Continuity to metallic water lines
DL
Continuity to metallic ventilation systems
D1, D2, D3, D4
Continuity to other, user-defined types of metallic systems
U
Contact resistance measurement at all measuring points in order to
determine continuity of all conductors. The number assigned to the
measurement designates resistance between specific test joints, e.g. mea-
surement number 1 indicates resistance between test joints 1 and 2, mea-
surement 2 between test joints 2 and 3 etc.
E
Measurement of earth dissemination resistance from individual earth
electrodes with open test joints
!
Measurement of earth dissemination resistance for the entire system
with closed test joints
25

Publicidad

Tabla de contenido
loading

Tabla de contenido