5.4
Faults – Rectification of minor faults not requiring customer service
Faults affecting operation of the FALCO EVO 622/622 IT may occur in the course of normal working. The following table
lists possible faults not requiring the attention of a customer service engineer.
i
To take action as quickly as possible it is important to quote the details on the rating plate (label on back of
FALCO EVO 622/622 IT) and the nature of the problem when calling.
!
Work on the electrical, hydraulic and pneumatic system is only ever to be performed by appropriately qualified
personnel.
i
If the problem cannot be solved on the basis of the information below, please contact customer service.
Faults
Tool column
Roller of mounting head blocked.
Clamping plate / rails / clamping jaws
Clamping plate will not turn in any direction.
Clamping plate turns in counter-clockwise direc-
tion.
Insufficient clamping plate
torque.
Rim not correctly held in position by rails.
Rim not correctly held in position by clamping jaws. R Make sure the grippers are in proper working order. Replace if worn.
Unseating unit
The unseating unit does not exert enough unsea-
ting force.
Tab. 6:
Faults
Sicam srl società unipersonale
Operation | FALCO EVO 622/622 IT | 51
Roller not lubricated or dirty: Clean and then lubricate roller.
R Check whether the mains voltage corresponds to the voltage on the rating
plate.
R Check that the mains connector is properly plugged in.
Interchange 2 phases in the mains connector (qualified electrician only).
R Check whether the mains voltage corresponds to the voltage on the rating
plate.
R Check for proper connection of the phases in the connector (qualified elec-
trician only).
R Check whether the machine is properly connected to the compressed air
system.
R Check that the system pressure is not below the minimum machine opera-
ting pressure value (see Sec. 8).
R Set the machine operating pressure at the filter assembly to the values re-
commended by the manufacturer.
R Check whether the machine is properly connected to the compressed air
system.
R Check that the system pressure is not below the minimum
FALCO EVO 622/622 IT operating pressure value (see Sec. 8).
R Set the machine operating pressure at the filter assembly to the values re-
commended by the manufacturer.
R Completely deflate the tire before unseating.