7.
Decommissioning
7.1
Change of location
1. Unplug the electrical connection.
2. Unfasten the compressed air connection.
3. Heed the notes on commissioning (Sec. 4).
4. Use the four bolts supplied to secure the
FALCO EVO 622/622 IT on the pallet again (Section
4.2.7).
i
On the sale or transfer of ownership of the
FALCO EVO 622/622 IT, all the documentation con-
tained in the scope of delivery is to be handed over
together with the FALCO EVO 622/622 IT.
7.2
Temporary shutdown
Always unplug the mains connector from the socket
if the FALCO EVO 622/622 IT is to be temporarily shut
down or if it is not being used for some other reason.
i
It is advisable to thoroughly clean the
FALCO EVO 622/622 IT as well as the corresponding
tools and accessories and to provide protection (e.g.
by applying a thin film of oil).
7.3
Disposal
¶
Disconnect the FALCO EVO 622/622 IT from the power
supply.
¶
Disconnect the power cord.
¶
Oils can contaminate water and must be disposed of
in accordance with the applicable regulations.
¶
Dismantle the FALCO EVO 622/622 IT and sort out and
dispose of the different materials in accordance with
the applicable regulations.
The FALCO EVO 622/622 IT is subject to EU
directive 2002/96/EC (directive on the dis-
posal of electrical and electronic waste).
Electrical and electronic devices, including
cables, accessories and batteries, must
be disposed of separately from household
refuse.
¶
Use is to be made of the return and collec-
tion systems provided for the disposal of
such equipment.
¶
Proper disposal of the
FALCO EVO 622/622 IT can help to prevent
environmental pollution and possible
health hazards.
Sicam srl società unipersonale
Decommissioning | FALCO EVO 622/622 IT | 55
8.
Technical data
8.1
FALCO EVO 622/622 IT
Function
Max. noise level
Force of unseating cylinder
Compressed air supply
Power supply
8.2
Temperatures and operating range
Function
Operating temperature
Storage temperature
Temperature gradient
Relative humidity in operation
Relative humidity gradient
Installation height
Transportation height
8.3
Operating range
8.3.1
Car tires
Function
Tire width
Max. tire diameter
Rim diameter (clamping on inside)
Rim diameter (clamping on outside)
en
Specification
70 dB
11,5 kN "
8 – 10 bar
Depending on voltage
ordered (refer to rating
plate)
Specification
-5° C \ +40° C
-20° C \ + 60° C
20° C
10% \ 90% (40° C)
10%
-200 mt. \ 3.000 mt.
-200 mt. \ 12.000 mt.
min / max
3 - 12,5 inch
1100 mm
10 - 22 inch
12 - 24 inch
|
1 695 101 508