Descargar Imprimir esta página

Festo HSP Serie Instrucciones De Utilizacion página 46

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 63
HSP−...
Fitting: Electric components
Use proximity switches SME/SMT−8 for
scanning the end positions:
1. Remove the protective cover of the
handling module.
2. Make sure that the shock absorbers are
screwed in completely (as supplied from
the factory).
3. Push the proximity switch into the groove
of the sensor rail (A).
The electric proximity switches are trig
gered by magnets in the stop screws (B).
4. Fasten the proximity switches in the end
positions. Subsequent adjustment of the
shock absorbers is not necessary.
Please note
The cables of the proximity switches must not lie in the working range of the
handling module.
S Clamp the cables in the groove of the side plates (D) and the sub−base.
S Secure the cables with the aid of the cover profile (C) of the installation kit
(cut to size).
S Paass the cables back through the through hole in the sub−base (E).
46
(E)
(A)
Fig. 19
Festo HSP−... 0308 NH English
(D)
(C)
(B)

Publicidad

loading