HSP−...
Test
Test cycle
Sign of wear
Replacement
cycle
*)
At 0.5 Hz in dual operation mode.
Check to see if more frequent tests are required. This may be the case with:
S
higher temperatures
excessive dirt
solvent liquids or fumes.
Please note
If the load changes, repeat the test taking the modified work load into
consideration.
End position adjustment (chapter Fitting")
Setting the positioning speed (chapter Commissioning")
9
Care and maintenance
Check regularly the shock absorber and the spring clamping elements.
S
If the HSP−... is dirty, clean the exterior with a soft cloth.
S
If the HSP−... is defective or if the drive on the HSP−...−AP is defective:
Send the HSP−... to Festo for repairs.
S
52
Spring clamping element 1
Every 2 million strokes
(approx. every 2 months)
Play of the vertical guide rail in
the end positions in a horizontal
direction
After 5 million cycles
Shock absorber 2
Every 2 million strokes
*)
(approx. every 2 months)
Oil leakage; hard knocking;
stop plunger remains in the
retracted end position or moves
away from it only hesitantly.
Every 10 million strokes
(approx 1 year)
Festo HSP−... 0308 NH English
*)
*)