In the event of a fault
Recommended action
Check whether....
1.
the device is connected to the mains.
2.
all the cables are correctly plugged in.
3.
4.
the cable or plug shows signs of damage.
5.
you have established contact between the radio remote control and the motor.
6.
the control box has the correct type designation.
Continue to identify the source of the fault.
If the bed system still does not function correctly or there is damage to the cables and/or
plugs, please contact our Customer Service.
Please note:
Replacement parts covered by the warranty are despatched free of charge by post where these are plug-
in components (i.e. manual switch, remote control, control box, cable). Extensive malfunctions which are
Due to the technical design, it is generally not necessary to replace the entire motor frame. Parts deliveries
and services are chargeable when the warranty has expired and are payable in advance.
As of: 09/2013
OCTO Actuators GmbH
de Werth Str. 1
D-97947 Grünsfeld
Tel.
+49(0) 9346 9276 - 222
Fax
+49(0) 9346 9276 - 223
Identifying the source of a fault
Proceed as follows:
Press the motion control button on the remote control/manual switch:
Head/back area
Is the motor audible?
Yes
Is the motion control operating?
Yes
Feet/thigh area
Is the motor audible?
Yes
Is the motion control operating?
Yes
Yes/No/Yes/Yes
Contact Customer Service
Yes/No/Yes/No
Contact Customer Service
Yes/Yes/Yes/No
Contact Customer Service
No/No/Yes/Yes
Probably a malfunction on the manual switch
Yes/Yes/No/No
If you have two bed systems, swap the manual
switch over to test it.
You will receive a new manual switch/remote con-
trol as a replacement
No/No/No/No
Repeat steps 1,2,3,4 and 5:
Manual switch/remote control or control box is
faulty.
If you have two bed systems, swap the manual
switch over to test it. You will receive a new manual
switch/remote con
If you have two bed systems, swap the control box
over to test it. You will receive a new control box as
a replace ment.
.
No
No
No
No
trol as a replacement.