Digital Inputs - Lenze L-force Drives 9400 E94BSHE Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Digital inputs

Terminal X5
9400SSP000X5
Terminal data
Flexible
With wire end
ferrule
Diagnostics/keypad
Terminal X6
9400SSP000X6
Resolver
Terminal X7
9400SSP000X7
Note regarding the connection of motor temperature sensors to "KTY"
Standard setting: KTY 83−110
ƒ
Parameterisation also supports: PT1000 and PT10000/2 PTC's
ƒ
– HighLine from SW−V14.xx onwards
– ServoPLC from SW−V08.xx onwards
EDK94SH366 DE/EN/FR/ES/IT 7.0
Labelling
Description
GI
GND digital in
RFR
Controller enable
DI1
Digital input 1
DI2
Digital input 2
DI3
Digital input 3
DI4
Digital input 4
DI5
Digital input 5
DI6
Digital input 6
DI7
Digital input 7
DI8
Digital input 8
Conductor cross−section
2
[mm
]
0.2 ... 2.5
Labelling
Description
Internal interface, RJ69 socket, for keypad or diagnostic adapter
Labelling
Description
1
+REF
2
−REF
3
V
CC
4
+COS
5
−COS
6
+SIN
7
−SIN
8
+KTY
9
−KTY
l
Wiring the device
Control terminals
Tightening torque
[AWG]
[Nm]
24 ... 12
Spring terminal
6
[lb−in]
127

Publicidad

Tabla de contenido
loading

Tabla de contenido