ELECTRONICAL CONTROLLER
By default the forward movement speed is displayed on the monitor. When
some abnormal readings are shown, the screen will display "Alarm" intermit-
tently, the alarm will sound and the corresponding malfunction channel will
be activated. The alarm will not stop until the malfunction is fixed.
To display a desired reading, press the central button and scroll to the re-
quired channel. After 10 seconds, the reading will change back to C1 again.
10.2 FORWARD SPEED – C1
Select a channel by using the central button. The alarm is activated when the
speed is under 2.6 km/h and can be turned off using programming mode 2.
Calibrating the speed sensor
Theoretical calibration is achieved by entering a calibration factor in pro-
gramming mode 2, as indicated in the following table.
MODEL
4M
4.5M
5M
6M
CALIBRATION FACTOR
1,818
1,574
1,449
1,258
Selecting speed channel (C1)
1. Press
to switch to mode 1. While holding the button, press the
central button
to modify the digit.
2. Hold the central button for some seconds to modify the flickering digit.
3. When the buttons are released, the monitor will return to its normal state.
60