SC230
ELECTRICAL CONNECTIONS: FASTONS
Position
Signal
Description
1
CN2 CN3
Ground connection
2
CN4 CN5
Motor capacitor connection
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
M1
2
NEUTR
3
4
M2
5
6
7
8
9
10
PHOTO
M3
11
SAFETY
12
13
14
15
24 VAC
16
M4
WARNING
17
18
19
20
M5
21
PROTECTION FUSES
Position
Value
Type
F1
500 mA
FAST
F2
3,15A
FAST
F3
500 mA
FAST
Signal
Description
PHASE
230 VAC power supply
230 VAC power supply
Flashlight output 230 VAC 40W
LAMP
LAMP
Flashlight output 230 VAC 40W
COM
Motor common
OPEN
Motor connection (opening)
CLOSE
Motor connection (closing)
PED
PEDESTRIAN input (N.O.)
START
START input (N.O.)
PHOTOCELL input (N.C.). If not used, jumper with terminal 13
SAFETY DEVICE input (N.C.). If not used, jumper with terminal 13
STOP
STOP input (N.C.). If not used, jumper with terminal 13 or set dip switch 10 to ON
COM
COMMON INPUTS/OUTPUTS
GND
External accessory power supply and in ductive sensor ground (blue cable)
24 VAC external accessory power supply (photocells, radio, etc.)
SEC
24 VAC external safety device power supply present only during the operating cycle
WARNING LIGHT output 24 VAC 3W max
LIGHT
12V
Inductive sensor positive power supply (brown cable)
IMP
Inductive sensor input (black cable)
GND
ANTENNA GROUND input
ANT
ANTENNA SIGNAL input
Description
Protects the ACCESSORY and SAFETY DEVICE power supply outputs
Protects the control unit at the 230 VAC power supply input
Protects the flashlight output
Slow flashing in opening, turned off in pause, fast
flashing in closing.
Slow flashing in opening, turned off fixed in pause, fast
flashing in closing.
11
UK