Default Settings; Trimmer Adjustment - GiBiDi SC230 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
SC230

DEFAULT SETTINGS

DIP 1 and DIP 2 both OFF: Step-by-step with stop
DIP 3 OFF: Pre-flashing disabled
DIP 4 OFF: Safety device test disabled
DIP 5 OFF: Opening photocell disabled
DIP 6 OFF: Automatic closing disabled
DIP 7 OFF: Deceleration disabled
DIP 8 OFF: Fast closing disabled
DIP 9 OFF: Motor rpm sensor disabled
DIP 10 OFF: STOP input enabled
Closing limit switch
motor stop

TRIMMER ADJUSTMENT

The trimmers TR2, TR3, TR4, TR5 can be adjusted also during gate movement and hence the effect
immediately be checked.
The trimmer TR1 is stored only during the rest phase (gate closed).
Trimmers
Function
TR1
PAUSE
TR2
FORCE
TR3
SLOW
TR4
AMP .FORCE
TR5
AMP . SLOW
DEFAULT SETTINGS
•TRIMMER TR1 adjusted to minimum
•TRIMMERS TR2, TR3 adjusted to half position
•TRIMMERS TR4, TR5 adjusted to maximum
500 600mm
Limit switch slowing
down in closing
Description
Adjusts the PAUSE TIME from 2 to 215 seconds. The value is increased by turning the t rimmer clockwise.
Adjusts the motor FORCE level. The force is increased by turning the trimmer clockwise.
Adjusts the DECELERATION level. Turning clockwise the gate speed/force is increased.
Adjust the motor rpm sensor sensitivity during non-decelerated motion.Turn the trimmer clockwise to reduce sensiti v ity
Adjust the motor rpm sensor sensitivity during decelerated motion. Turn the trimmer clockwise to reduce sensitivity.
Opening limit switch
motor stop
Limit switch slowing
down in opening
WARNING: With some motorizations, in function of gate's
characteristics, it could happen that with max.
deceleration the motor vibrates a little. In this case it is
necessary to adjust oppor tunely the deceleration's
trimmer avoiding to position it at the max.
13
UK
Fig.2
Fig.2

Publicidad

Tabla de contenido
loading

Tabla de contenido