1 | Safety Instructions and Guidelines
Incorrect
Clamping length too short, projection
length too long
Clamping Ø too large
Workpiece too heavy and jaw step too
short
Clamping Ø too small
38 / 138
Correct
Additional support with centre or
bezel
Insert larger chuck
Support with centre, jaw step
extended
Clamping on largest possible
clamping Ø
RN-1391