The first time the system is started up, some parameters must be set. In particular, starting from the screen in fig.4.2,
press the Password button and enter the code 7388.
Then continue by pressing the "power source setup" button; the following screen will appear:
Then continue by pressing the "Advanced Settings" button; the following screen will appear:
Then enter the correct settings for your system, following the instructions shown in Fig.4.4 in the System Configuration
box.
In particular, in addition to displaying the torch model fitted in the system, also set:
♦
Gas cable Length: set the length of gas connection Item No 1166 in metres
♦
Plasma Valve Console: select the model from the options Item No 469, 459, 462 or 464
♦
Water Secondary Console: if WSC Item No 485 is present, set to ON
♦
Postflow Time: set the duration of torch cooling after cutting in seconds
♦
MARK from CNC I/O: if a marking mode command is issued by the CNC, set Enabled
♦
SPOT from CNC I/O: if a spot marking mode command is issued by the CNC, set Enabled
♦
Language: select the required language
♦
Light theme: to select black wording on a light background, set Enabled
Fig. 4.3
Fig. 4.4
109/128