Code
TYPE
Error Description
81
[E]
Gas console not connected to the power
source
82
[E]
No connection between PGC-D and PGC-H2
or APGC
85
[W]
Error during USB firmware updating
90
[W]
CNC off, in emergency status or not connected
to power source
90
[E]
Emergency A or Emergency B button pressed Exit emergency status
93
[W]
Coolant temperature too high
ACTION
Contact the CEBORA Service Department
Check the connection between PGC-D and
PGC-H2 or the internal connection between the
upper and lower APGC
Switch off the power source, wait 10 seconds
and restart the power source.
If the problem persists, contact the CEBORA
Service Department.
Turn on the CNC, exit emergency status, check
the power source-CNC connection.
Check for blockages in the coolant circuit pipes
or torch.
Check the pump fuse is intact.
Clean the radiator.
123/128