B
C
A
Fig. 3.4
Fig. 3.1
Insert connection Item No 1169, with its cables, into the power source torch attachment G and fully tighten the 3
retaining screws. Tighten the black power cable to terminal B (-), insert the two safety cables into terminal unit C and
the faston of the pilot arc red cable into cable A with the male faston.
Screw the earth cable terminal into terminal H (+) as shown in the figure and the cooling water pipes E and F, taking
care to match the colour (E-red = hot water, return; F-blue = cold water, delivery).
Insert the other end of connection Item No 1169 into unit HV19/1 (Item No 464) as shown on the right side of figure
3.3 (black power cable to terminal B (-) and faston of pilot arc red cable in A. Unit HV19/1 must be connected to earth
directly on the pantograph (using the 4 retaining screws shown in figure 6) and positioned in such a way as to allow
the pantograph to open.
B
Fig. 3.3
A
With reference to Fig. 3.4, connect Item No 1189 to connector B (in relation to the gas console); the pantograph con-
nection to connector A ; lastly, connect Item No 1199 (if applicable) to connector C (for the remote panel).
92/128