Complete The Finished Wall - Kohler K-306 Guia De Instalacion

Ocultar thumbs Ver también para K-306:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1/2"
(1.3 cm)
2-1/4" to 3"
(5.7 to 7.6 cm)
Rough-In Depth

2. Complete the Finished Wall

CAUTION: Risk of product damage. This valve contains plastic
and rubber components that may become damaged if soldering
heat is applied directly to the valve body.
CAUTION: Risk of damage to the K-306-KS valve assembly.
When using the K-306-KS HiFlow Valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
NOTE: Thick wall installations are typically tile, plaster, marble, or
similar materials. Thin wall installations are typically fiberglass and
acrylic.
NOTE: Do not adjust the maximum water temperature at this time.
Thick Wall Installation
Provide a 5-9/16" (14.1 cm) diameter hole in the wall material.
The flat front surface of the plaster guard must be flush with the
finished wall.
Complete the finished wall.
Kohler Co.
Finished
Wall
5-9/16" D.
(14.1 cm)
Plaster Guard
Dome
5
Attachment Hole
Backing Plate
Outer Ring
Valve Stem
Dome
Backing Plate
2-1/4" (5.7 cm)
Rough-In Depth
Plaster Guard
Finished
Wall
4" D. (10.2 cm)
Plaster
Guard
1012679-2-C

Publicidad

Tabla de contenido
loading

Tabla de contenido