Descargar Imprimir esta página

Lamborghini Caloreclima ECO 15 Manual Para La Instalación Y El Mantenimiento página 42

Quemadores para gasóleo

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

PIPE FILTER
Close the fuel aspiration gate and, depending on the type, proceed with thorough cleaning of the filtration
component. To check whether the air gate fan is clean or to check the combustion head proceed as follows:
-
Remove the cover (23) by loosening the screw (22).
-
Loosen the lower screws (32) completely.
-
Loosen the central screw too.
-
Parzially loosen the upper screws (14) too.
-
Release by raising the component support plate (34) and hook it in its seat as illustrated in fig. 16.
Doing the above provides the conditions needed to check whether the internal burner parts are clean and,
where necessary, to replace the motor-fan unit. When re-assembling make sure that you observe the gap
illustrated in fig. 15.
WARNING: in the event of a dangerous situation cut power by turning the main switch to OFF and stop fuel
flow via the relative gate.
42
Fig. 16

Publicidad

loading

Este manual también es adecuado para:

Eco 20Eco 15/2Eco 20/2