Operating Instructions Safety Switch NZ.VZ
Technical data
Parameters
Value
Housing material
Anodized die-cast alloy
Degree of protection acc. to IEC 60529
NZ1VZ...
IP67
NZ2VZ...
IP65 (mating connector tightened)
Mech. operating cycles
2 x 10
6
Ambient temperature
-25 °C ... +80 °C
Installation position
Any
Approach speed, max.
20 m/min
Approach speed, min.
0.02 m/min (NZ.VZ-511...)
Actuation frequency
7000 / h
Actuating force at 20 °C
35 N
Extraction force
35 N
Retention force
10 N
Weight
approx. 0.3 kg
Switching principle switching elements
511
Snap-action switching contact
528, 538, 2121, 2131, 3131 Slow-action switching contact
Contact material
Silver alloy, gold flashed
Connection type
NZ1VZ...
Screw terminals M20 x 1.5
NZ2VZ...
Connector
Connection cross-section (rigid/flexible)
NZ1VZ...
0.34 ... 1.5 mm
NZ1VZ...L (with indicator LED) 0.34 ... 0.75 mm
Conductor cross-section mating connector
SR6 (NZ2VZ-5...)
0.5 ... 1.5 mm
2
SR11 (NZ2VZ-2.../NZ2VZ-3...)
0.5 mm
Rated insulation voltage
NZ1VZ.../NZ2VZ-5...
U
= 250 V
i
NZ2VZ-2.../NZ2VZ-3...
U
= 50 V
i
Rated impulse withstand voltage
NZ1VZ.../NZ2VZ-5...
U
= 2.5 kV
imp
NZ2VZ-2.../NZ2VZ-3...
U
= 1.5 kV
imp
Rated short-circuit current
100 A
Degree of contamination
3 (industrial)
(external, acc. ?to EN 60947-1)
Switching current min.
At switching voltage:
DC 24 V
NZ.VZ-511...
10 mA
NZ.VZ-...
1 mA
Utilization category to IEC 60947-5-1
NZ.VZ-511...
AC-15 6A 230V / DC-13 6A 24V
NZ1VZ.../NZ2VZ-5...
AC-15 4A 230V / DC-13 4A 24V
NZ2VZ-2.../NZ2VZ-3...
AC-15 4A 50V / DC-13 4A 24V
Conventional thermal current I
th
NZ.VZ-511...
6 A
NZ.VZ...
4A
Short circuit protection (control circuit fuse)
NZ.VZ-511...
6 A gG
NZ.VZ...
4A gG
Indicator LED (only with switching element 511, 528, 538)
L060
AC/DC 12 ... 60 V
L110
AC
L220
AC
Limitations at ambient temperature above +70 ... 80 °C
Utilization category
NZ2VZ-5...
AC-15 2A 230V / DC-13 2A 24V
NZ2VZ-2.../NZ2VZ-3...
AC-15 2A 50V / DC-13 2A 24V
Conventional
2 A
thermal current I
th
Short circuit protection
2 A gG
Reliability figures according to EN ISO 13849-1
B
4.5 x 10
6
10d
Z-L
2
2
2
DC 12 V
-
10 mA
110 V (±15 %)
230 V (±15 %)
Figure 5: Min. door radii
Hinged actuator Z-L / Z-R
30
Z-R
Hinged actuator Z-U / Z-O
50
40
16
20
8
Z-U
Actuator type
ACTUATOR-Z-G...
HINGED ACTUATOR-Z-R
HINGED ACTUATOR-Z-L
HINGED ACTUATOR-Z-.-C2194
HINGED ACTUATOR-Z-U
HINGED ACTUATOR-Z-O
Hinged actuator Z-L-C2194 / Z-R-C2194
50
40
Z-L
Z-R
50
40
16
20
8
Z-O
Door radius min. [mm]
1000
400
400
200
165
165
14
Ø 5,5