7.2 Connection diagram for the AR control unit

2
2
3
1
4
2
2
3
3
1
5
4
1
3
Fig. 7
Connection diagram

7.2.1 Diaphragm leakage detection / dosing controller

Socket 1
For diaphragm leakage detection (MBS) and/or dosing controller
(DC).
The diaphragm leakage detection and dosing controller are
pre-assembled with an M12 plug for socket 1.
If the diaphragm leakage sensor and the dosing controller are to
be used at the same time, both cables must be assembled in one
plug.
Warning
For the connection of one cable, use a plug adapter
with simple cable entry, for the connection of two
cables, use a plug adapter with double cable entry,
otherwise the protection will be lost!
Connect the cables according to the following table.
Socket 1
Pin
Assignment
1
+12 V
2
MBS/GND
3
MBS supply
4
Dosing controller output
5
MBS output
* MBS is an abbreviation of the function in German language "Membranleckagesignalisierung" = diaphragm leakage detection

7.2.2 Current output / remote on/off

The current output is not designed for controlling
Caution
secondary pumps in master/slave operation.
Socket 2
For the remote on/off input and current output.
Socket 2
Pin
Assignment
1
+5 V
2
Remote on/off input
3
GND
4
Current output
4
5
2
3
1
1
4
3
1
4
2
Diaphragm leakage detection (MBS)*
Cable 0.8 m
Green/yellow
Wire colour
Used for / wire colour
Cable 3 m
(without plug)
White
White
Blue
Yellow
Green
Cable
+/- current output
Brown
White
Blue
Black

Dosing controller

Brown
Blue
Used for
Remote on/off
+
x
x
-
11