EN
1.5
Technical features
DESCRIPTION
CERTIFICATIONS
Country of intended installation
Fuel
PIN number
Category
Type
Class NO
x
HEATING PERFORMANCE
HEAT INPUT
Nominal
Minimum
HEAT OUTPUT
Nominal (80-60°C)
Minimum (80-60°C)
EFFICIENCY
Max useful efficiency (80-60°C)
Min useful efficiency (80-60°C)
Useful efficiency at 30% of load (50-30°C)
Thermal efficiency (EEC 92/42)
Losses after shutdown at 50°C
DOMESTIC HOT WATER PERFORMANCE
Nominal heat input
Minimum heat input
D.H.W. flow rate ΔT 30°C
Continuous D.H.W. flow rate (ΔT 25°C / ΔT 35°C)
Minimum D.H.W. flow rate
Max / Min Pressure
ELECTRICAL SPECIFICATIONS
Power supply voltage
Frequency
Absorbed electrical power
Electrical protection degree
COMBUSTION DATA
Smoke temperature at Max/Min flow (80-60°C)
Smoke flow Max/Min
CO
at Max/Min (G20) flow rate with separate chimneys
2
CO
at Max/Min (G31) flow rate with separate chimneys
2
NOZZLES - GAS
Number of nozzles
Nozzle diameter (G20)
Nozzle diameter (G30/G31)
Gas consumption at Max/Min flow rate (G20)
Gas consumption at Max/Min flow rate (G30)
Gas consumption at Max/Min flow rate (G31)
Gas supply pressure (G20/G30/G31)
TEMPERATURE - PRESSURE
Max operating temperature
Heating adjustment range
Domestic hot water adjustment range
Max operating pressure
Water content in boiler
Lower Heat Output (Hi)
9.45 kW/m
(15°C, 1013 mbar) - G30 Hi. 12.68 kW/kg (15°C, 1013 mbar) - G31 Hi. 12.87 kW/kg (15°C, 1013 mbar)
G20 Hi.
3
C12 - C12X - C32 - C32X - C42 - C42X - C52 - C52X
C62 - C62X - C82 - C82X - C92
kW
kW
kW
kW
%
%
%
W
kW
kW
l/min
l/min
l/min
bar
kPa
V
Hz
W
IP
°C
g/s
%
%
No.
mm
mm
m
/h
3
kg/h
kg/h
mbar
kPa
°C
°C
°C
bar
kPa
l
Brava Slim 40 BF
IT – ES – PT – GR – SI
G20 - G30/G31
1312CP5935
II2H3+
B22P - B32P - B52P
3 (< 150 mg/kWh)
40,0
13,5
37,2
11,3
93,0
83,6
91,7
88
40,0
13,5
17,8
21,3 / 15,2
2,2
7 / 0,4
700 / 40
230
50
136
X5D
147/91
23/26
7,4/2,1
8,1/2,6
16
1,40
0,81
4,25/1,40
3,15/1,06
3,10/1,04
20 / 28-30 / 37
2 / 2,8-3 / 3,7
85
20 ÷ 80
10 ÷ 60
3
300
4,90
75