SC24
6 - ELECTRICAL CONNECTIONS: FASTON
Faston
Description
0 Vac
Transformer 0 Vac connection (black cable).
18 Vac
Transformer 18 Vac connection (orange cable).
24 Vac
Transformer 24 Vac connection (red cable).
7 - PROTECTION FUSES
Position
Value
F1
315 mA
FAST-BLOW
F2
5 A
FAST-BLOW
F3
500 mA
FAST-BLOW
8 - DIP SWITCH SW1
The settings are stored during the rest phase (gate closed
The DEFAULT settings are coloured in grey .
DIP
Function
STEP–BY-STEP
WITH STOP
STEP–BY-STEP
DIP1
DIP 2
CONDOMINIUM
DEAD MAN
Type
Description
Protects the ACCESSORY and SAFETY DEVICE power supply.
Protects the control unit at the 24 VAC power supply input.
Protects the flashlight output.
Status
Description
Operation in reply to a START command
• Gate closed
• During opening
OFF
OFF
• Gate open
• During closing
• After a STOP
Operation in reply to a START command
• Gate closed
ON
• During opening
OFF
• Gate open
• During closing
Operation in reply to a START command
• Gate closed
• During opening
OFF
ON
• Gate open
• During closing
• If START button is held down
• If PEDESTRIAN button is held down
ON
The SAFETY 8K2, PHOTO inputs and the decelerations will not be active.
ON
STOP 8K2 will be enabled.
Not manageable with radio control.
).
:
→ OPENS
STOPS
→
→ CLOSES
STOPS
→
→ inverts the motion
:
→ OPENS
→ CLOSES
→ CLOSES
OPENS
→
:
→ OPENS
→ IRRELEVANT
Recharges the automatic closing time if the automatic
→
reclosing is enabled, otherwise closes
→ OPENS
OPENS
→
CLOSES
→
13
UK
.