Grundfos DMH 28X Instrucciones De Instalación Y Operación página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 103
1. Loosen the dosing head deaeration screw (V) by approx. 1
turn.
2. Fit the hose (1j) supplied with the pump onto the deaeration
nipple (I).
3. Using the syringe (Z) supplied with the pump, carefully draw
the dosing medium until there is some liquid in the hose.
4. Tighten the deaeration screw (V).
5. Remove the hose (1j) and the syringe (Z).
6. Set the stroke-length adjustment knob to 70 % and let the
pump run for approx. 5 minutes.
7. Switch off the pump, check the oil level and add oil, if
necessary.
8. Refit the oil filling screw (F).
9. If already dosing, the pump is now ready for operation. If the
pump is not dosing, deaerate the piston flange.
Deaerating the piston flange
Y
E
1e
V
Fig. 24 Deaerating the piston flange
Pos.
Components
1q
Dosing head screws
2
Dosing head
3b
Discharge valve
F
Oil-filling screw with dipstick
L
Stroke-length adjustment knob
1l
Cover for stroke-length adjustment knob
M
Pressure relief valve
V
Deaeration screw
I
Hose nipple (connection for J)
J
Deaeration hose (not supplied with the pump)
1m
Cover for pressure relief valve
2m
Adjusting screw
3m
Pressure relief valve
4m
Spring
E
Degassing valve (cartridge)
1e
Adjusting screw
Y
Holes
1. Unscrew the cover for the pressure relief valve (1m).
2. Measure the adjustment depth (h) of the adjusting screw (2m).
3. Unscrew the adjusting screw (2m).
4. Remove the pressure relief valve (3m) with spring (4m).
5. Unscrew the whole degassing valve (cartridge) (E) using a
fork wrench, size 14.
24
1m
h
2m
3m
4m
Y
Do not turn the inner slotted screw (adjusting screw
Caution
(1e)), as this changes the degassing valve setting.
6. Connect the electrical power supply.
7. Let the pump run for approx. 5 minutes at a stroke setting of 0
% until oil (without bubbles) appears around the holes (Y).
Add oil, if necessary.
8. Switch off the pump and screw in the degassing valve (E) with
front side O-ring.
9. Refit the pressure relief valve (M/2m, 3m, 4m) in reverse
order. Set the adjusting screw to the depth (h) already
measured.
10. Set the stroke-length adjustment knob to 70 % and let the
pump run for approx. 5 minutes.
The pump is now ready for operation.
Checking the degassing valve (cartridge)
The degassing valve (E) only operates with the
spring (5e), ball (6e) and correct position of the
Note
adjusting screw (7e).
Check the setting of the degassing cartridge when the pump is
switched off:
Fully tighten the adjusting screw (7e) and then loosen by
approx. 1/4 turn!
Fig. 25 Degassing valve
Pos.
Components
5e
Spring
6e
Ball
7e
Adjusting screw
Rod length of oil dipstick: 27 mm.
Note
Immersion depth to marking: approx. 5 mm.
Check the oil level at least every two weeks and add
oil, if necessary.
Only use original Grundfos gear oil!
Note
For product numbers, see "Service kit catalogue" on
www.grundfos.com
Pump model
Version
DMH 280
Single/double
After start-up
After initial start-up and after each time the
diaphragm is changed, tighten the dosing head
screws.
Caution
After approximately 6-10 operating hours or two
days, cross-tighten the dosing head screws using a
torque wrench.
Torques
Pump model
DMH 280
7e
5e
6e
Description
1.3 l DHG 68
Torque
[Nm]
55-60

Publicidad

Tabla de contenido
loading

Tabla de contenido