Zodiac eXPERT Manual De Instalación Y De Uso página 51

Ocultar thumbs Ver también para eXPERT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 167
2.1.2. Connecting the cell and the sensor holder
• Do not glue sensor holder and cell directly together : use a PVC union coupler (not included) between
sensor holder and cell.
It is also possible to use a 6-to-8 cm PVC tube, Ø63 cm, with one beveled end (the one to glue to the cell
inlet) and a PVC sleeve (to glue between the PVC tube and the sensor holder).
For connecting the cell and the sensor holder :
• Degrease the sensor holder, the cell inlet and the PVC union with PVC cleaner (not supplied).
• Glue the sensor holder and the female union and fit them into each other as far as it will go. Remove any excess glue
with a damp cloth.
• Glue the cell inlet and the male union and fit them into each other as far as it will go. Remove any excess glue with a
damp cloth.
PVC union
coupler
Connecting the cell and the sensor holder
2.1.3. Connecting the cell to the control box
• Open the cell protective cap by turning it anti-clockwise.
• Identify the function of each wire (red, yellow, orange) in the power cable.
PVC sleeve
PVC pipe (fitted
into the cell)
Cable colour
Function
Red
Electrolysis
Red
Electrolysis
Yellow
AUX / Conductivity
Orange
Temperature
EN
8

Publicidad

Tabla de contenido
loading

Tabla de contenido