11.3

Programming menu table

1. Programming Menu
Password
Enter password
1.1. Identifi cation
1.1.1. Admin/Filial PIN
Default 00000
1.1.2. Model
1.1.3. Version
1.1.4. Point of sale
Default 00000
1.2. Setup
1.2.1. Std temperature
Default: 100°C
1.2.2. Prog. doses
1.2.3. Prebrewing
Default: Medium
1.2.4. Filter coffee
Default: No
1.2.5. Descaling
1.2.6. Filter warning
Default: No
1.2.7. Credits
1.2.8. Language
Default: English
1.2.9. Grounds delay
Default: 5
1.2.10. Grounds control
Default: Yes
1.2.11. Contrast
Default: 35
1.2.12. Backlight
Default: 150
1.3. Stand-by
1.3.1. Activate?
Default: Yes
1.3.4. Stand-by delay
Default: 60
1.4. Cup warming
1.4.1. Activate?
Default: No
1.5. Security
1.5.1. Password
Default: 0000
1.6. Reset to default
1.6. Reset to default
Default: No
Installation of the machine - Service Provider Manual
Press ENTER to access the programming menu.
Value selected
Enter the previously entered and stored password (4 digits) to access the programming menu.
Default: 0000
Identifi es the Service Provider or Administrator's code: Numerical value between 0 and 65535.
(Read only) Identifi es the machine model.
(Read only) Identifi es the version of the machine's software.
Identifi es the point of sale: Numerical value between 0 and 65535. Enter the selected number. This number will then be
displayed.
Boiler operating temperature (in degrees centigrade) when the machine is ready for use. Values: 90-105.
1.2.2.1. Short prod.dose
Quantity for espresso coffee (this is a numerical parameter with no physical correspondent, e.g. cc).
Default: 140
1.2.2.2. Long prod.dose
Quantity for long coffee (this is a numerical parameter with no physical correspondent, e.g. cc).
Default: 173
1.2.2.3. Free prod.dose
Maximum amount of manually dispensed product (this is a numerical parameter with no physical correspondent, e.g. cc).
Default: 615
1.2.2.4. Bidose prod.dose
Quantity for double espresso coffee (this is a numerical parameter with no physical correspondent, e.g. cc).
Default: 210
Prebrewing time:
No, Short, Medium, Long.
"Yes" enables the fi lter coffee function. Filter coffee can only be brewed by pressing "ESC". The fi lter operation is not avai-
lable.
1.2.5.1. Water hardness
Values 0-4. "0" disables descaling checks. With hardness 1, 2, 3 and 4, descaling checks are activated and an alarm signal
Default: 3
will be shown after approximately 240, 180, 120 or 60 litres of water respectively have been processed. (Values from 5 to 9
will not be accepted)
1.2.5.2. Descal. warning
"Yes" enables display of the descaling alarm signal.
Default: Yes
"Yes" enables display of the fi lter replacement alarm signal. When enabled, the alarm signal shows after approximately 60 litres
of water have been processed, or in any event after 60 days.
1.2.7.1 Credit check
(Read only)
Default: No
YES: the machine continues to check remaining credits
No:The machine does not check remaining credit:
1.2.7.2 Credit warning
"Yes" enables:
Default: Yes
-
display of the credit alarm signal when the preset minimum number of credits is reached;
-
display of the "no credit" alarm signal when the credits have been used up.
1.2.7.3 Load credits
Number of credits added.
Default: 000
Value 0 - 255
Select language.
Time, in seconds, after which the machine resets used capsules (with the coffee grounds drawer removed); this delay is only
applicable if the respective alarm signal is shown. After this time the warning or the alarm signal is cancelled. Values: 0-255
seconds.
"No" disables control of the number of capsules dropped into the coffee grounds drawer. If the control is disabled, malfunctions
might occur.
Values 20-50.
To set the display contrast.
Valori 30-255.
To set the display brightness
"Yes" enables energy saving mode.
- When the machine is in standby mode, it switches off automatically after the defi ned time has elapsed following the last use.
- When the machine is in energy saving mode, the boiler temperature is reduced after the defi ned time has elapsed following
the last use.
Values: 5-240 minutes
Con "No" disables operation of the cup-warming surface (only for models equipped with a cup-warming surface).
Set menu access password
(4 digits)
"Yes" reverts to default values (factory presets)