Connection To The Electrical Power Mains - Fulgor Milano FUO 6009 MT MBK Instrucciones Para La Instalación Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 147

3 - Connection to the electrical power mains

EN
WARNING
This apparatus must be earthed.
The oven is only for domestic use.
The feed voltage and the absorbed power are as indicated on
the data plate attached to the left-hand side upright, which can
be seen when the oven door is open.
Connecting must be carried out by qualified personnel and in
accordance with the regulations currently in force.
The manufacturer can not be held responsible for any
damages to persons or objects caused by failure to observe
these instructions.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
The oven must be connected to the mains through a multipole
circuit breaker with a contact-to-contact gap of at least 3
mm, making sure that the earth wire is not disconnected. For
connecting use a flexible cable remembering to make it long
enough to allow the oven to be removed from its housing unit
when maintenance work is required.
Such a device must be fitted to the power supply in compliance
with the regulations
governing electrical installations.
The socket or switch must be easily reachable with the oven
fully installed.
6
CABLE TYPES AND MINIMAL DIAMETERS
H05RR-F
3x1,5 mm
2
H05VV-F
3x1,5 mm
2
H05RN-F
3x1,5 mm
2
H05V2V2-F 3x1,5 mm
2
SASO
H05RR-F
3x2,5 mm
2
H05VV-F
3x2,5 mm
2
H05RN-F
3x2,5 mm
2
H05V2V2-F 3x2,5 mm
2