Evaporative Cooling System
The center feed kit is an additional installation option and requires a separate order of
part number HSES-45.
1. Select and mark the center of the trough where 4" bulk head (HSES-45) will insert. Drill a 4" hole in
center of trough allowing room for lock nut of the tank adapter to fit. Insert the threaded end of the tank
adapter with one rubber gasket on the exterior and one on the interior of the trough. Securely tighten lock
nut inside trough.
HOLE SHOULD LEAVE A MINIMUM OF 2.75" FROM THE BOTTOM OF THE TROUGH
A SMALL SECTION OF THE TROUGH COVER DIRECTLY OVER THE 4" TANK ADAPTER MAY
HAVE TO BE REMOVED TO ALLOW TROUGH COVER TO SIT LEVEL ONTO TROUGH
2. Connect the Tank (HSES-40) to the bulkhead using the supplied flexible hose (HSES-39). 5 feet of hose
is supplied with each system. If additional hose is required please order separate. Using all (4) hose
clamps (620-072) secure hose to the bulk head and to the entry of the Tank as shown below in Figure 30.
Hog Slat Inc. Newton Grove, NC USA November 2018
SUBMERSIBLE PUMP END FEED
Tank Installation (Center Feed)
Figure 30