Evaporative Cooling System
4. Finally, place the tank cap (HSES-41) onto the tank. A section of the cap will have to be removed. An
example is shown below in Figure 36.
EXACT DIMENSION OF CUT SHOULD BE DETERMINED BY INSTALLER AS FEED PIPE AND SIZE
MAY VARY
Wire Connection:
Again, make sure that power is disconnected from system prior to servicing.
This Power Unit is supplied prewired for 230 volt operation with the proper rotation direction for correct motor
rotation. If 115 volt operation is required, please see wiring instruction on Motor Data Label for converting to 115
volt operation.
Black wire should be connected to L1(M1) and White wire should connect to L2(M2). Green should be connected
to Ground (See Figure 37)
Motor replacement and the associated wiring changes should only be made by qualified and properly
trained individuals.
Failure to follow the above warning can cause improper equipment function, premature failure of
equipment or electrical shock, leading to property damage or personal injury.
Hog Slat Inc. Newton Grove, NC USA November 2018
Figure 36
Pump Wiring Instruction
Figure 37
WARNING
ELECTRICAL SHOCK HAZARD!