Mitchell & Cooper crustastun CS01 Instalación Y Manual De Instrucciones página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

STUNNING THE ANIMAL
NORMAL STUN CURRENT
When stunning an animal, you should see
between two and six stun current indicator
lights illuminate. If not, please refer to the
troubleshooting guide (page 14).
The number of stun current indicator lights that
illuminate will vary according to the type, size
and age of the animal. Freshness, as well as
the season when the animal is caught, will also
effect the maximum stun current.
If a problem is detected during a stun cycle
you will hear four short alarm beeps. Refer to
troubleshooting guide for full details.
IF THE STUN CURRENT IS TOO LOW
The stun cycle stops with four short beeps and
the lowest current indicator flashes until the lid
is opened. Refer to the troubleshooting guide
for full details.
IF THE STUN CURRENT IS TOO HIGH
The stun cycle stops with four short beeps and
all of the current indicators flash until the lid is
opened. Refer to the troubleshooting guide for
full details.
10