Emergency Stop Button; We-6 Microcomputer; Led Display - Alliance Laundry Systems UW35P2 Manual De Operación

Ocultar thumbs Ver también para UW35P2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation
extractor, viewed from the front. The dispenser
has five supply compartments, numbered 1–5,
starting from the rear of the machine. The
compartments hold plastic supply cups that are
used for either liquid or dry supplies. A nozzle
flushes supplies from the cups with water for
the time programmed in the cycle.
Liquid supplies can be injected directly into
the cups by a customer-supplied external
chemical supply system. Five hose strain
reliefs on top of the supply dispenser facilitate
connection to an external supply system. A
terminal strip inside a compartment attached to
the left side of the control module, viewed
from the rear of the washer-extractor, provides
connection points for external supply signals.

Emergency Stop Button

A red emergency stop button is located on the
upper right-hand corner of the control panel.
Push the button in to stop the washer-extractor.
Turn button to the left and pull out to reset.

WE-6 Microcomputer

The WE-6 microcomputer control is a field-
programmable solid-state control capable of
storing and running up to 39 preprogrammed
ready-to-use cycles. A detailed description of
these cycles can be found in the Programming
section of this manual under Individual Cycle
Charts. (If this machine's computer has been
equipped with special preprogrammed cycles,
a separate insert listing these cycles has been
included in the resealable plastic bag which
contained this manual.)
Never turn the power off while the
computer mode switch is in the PROGRAM
position. Such action will disorder portions
of the programmed data, necessitating
14
reprogramming of some or all of the existing
cycles. Always return the mode switch to RUN
position before turning the power off.Never
leave the mode switch key inserted in the
switch lock where it may be accessible to
unauthorized personnel not familiar with
programming procedures.
The computer control in this washer-extractor
is continuously on the alert for problems
within the machine. When the computer
detects a problem, it immediately flashes a
letter or number or both on the display. It may
activate the signal buzzer as well.

LED Display

The WE-6 microcomputer has a six-digit LED
display. References to display indications
pertain to the first four digits of the display
reading left to right. The last two digits on the
right side of the display will indicate either the
last cycle used or the current cycle in progress.
See Figure 3.
Function
Step Number
Being
Executed
Figure 3
The table which follows, entitled "Display
Interpretations," lists the various displays and
what they mean.
Cycle Number
MC007A
F232090

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Uw35p3Uw60p2Uw60p3

Tabla de contenido