Handling And Unpacking; Unpacking; Handling And Storing - Berkel BV 400/25 Manual De Uso Y Mantenimento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 - BV 600/60
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 – BV 400/25H – BV 600/60
Rev. 01 - 04/2019 - Cod. 1500656 - Instruction manual for vacuum chamber packaging machines Mod. C46-C46H-C62
warNINg!
• Pay particular attention to staples, nails, rivets, sharp edges or anything else that could be a potential
hazard on the packaging. upon receiving the package, the Customer must verify its integrity, duly
reporting any anomalies, missing items or evident damage to the carrier or transport personnel. In
any case, this report must be made before any other handling or unpacking operation is implemented.
• any damage on the packaging could result in the appliance or its components being damaged. If in
doubt about the actual integrity of the appliance following transport, before any other operation, ask
your dealer or the manufacturer for information.
• The packed appliance must be stored in a protected place, which is dry, covered and not exposed
to weathering. The area in question must have a temperature range of 5°C to 40°C and a relative hu-
midity value that does not exceed 80%. Water and water vapour must be kept at a distance from the
installation or storage area.

4.1 uNPaCkINg

• After having removed the packaging, check the integrity of the appliance. If in doubt, do not use the machine
and contact the dealer immediately.
• Store the Velcro strap to tie the power cable to the relative support.
• It is recommended to store the packaging intact for any future handling or storage operations.
• Comply with that described in Chapter 3 for disposal and safety of the packaging material.

4.2 HaNdlINg aNd STorINg

warNINg!
• during transport and handling, the machine must always be kept in a horizontal position so
as to prevent the oil leaking from the pump.
• use the special plastic locking screws on the rear part to block the lid.
• Sealing bars and panels must be set in place so as to prevent them from moving inside the vacuum
chamber.
• If the appliance is stored, the area must be protected, dry, ventilated, covered and not exposed to
weathering.
• The area in question must have a temperature range of 5°C to 40°C and a relative humidity value that
does not exceed 80%
• water and water vapour must be kept at a distance from the installation or storage area.
warNINg!
after having been stored for a long time, perform the following operations:
• The pump oil must be replaced before starting-up, as described in the instructions found in the
"MaINTeNaNCe" chapter. The oil replacement must be carried out exclusively by authorised and
specialised personnel, in compliance with the instructions and the requirements in this manual.
• a dehumidification cycle must be run, as described in the "OPeRaTION" chapter.
14

4. HaNdlINg aNd uNPaCkINg

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bv 400/25hBv 600/60

Tabla de contenido