Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 – BV 400/25H – BV 600/60
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 - BV 600/60
Rev. 01 - 04/2019 - Cod. 1500656 - Instruction manual for vacuum chamber packaging machines Mod. C46-C46H-C62
5.6 CoNTrol PaNEl
1
1
PoS. CoMPoNENT
vaCuuM gaugE
1
( 0÷1 bar )
ON/OFF
2
THrEE-dIgIT
3
DOUBle DISPlay
CurSor
4
Prog
5
SEl
6
PuMP
7
SToP
8
lIquId ProduCT PaCkagINg
The vaC parameter is timed and expressed in seconds.
The vaC time setting must be suitable for actual operating requirements.
The time will be initially set approximately at 25-30 seconds and modified, if necessary, in the second cycle.
To obtain absolute vacuum, starting from the moment the vacuum gauge indicates -1.0 bar, the pump will
continue to run for another 10 seconds.
20
5
5
PROG
4
4
fuNCTIoN
• Measures vacuum in the vacuum chamber.
• Main switch with red indicator led: machine on/off and interrupt cycle.
• Top three digits: indicate the program entered or function activated:
Pr1 = program selected
vaC = vacuum
Sal = sealing
gaS = gas inlet
Sof = slow air return
JaR = jars function - (external containers and channelled bags vacuum).
• bottom three digits: indicate the value relative to the function activated and
the code of the options available: g = gaS / S = SOFTAIR; also indicates
the number of cycles performed andthe oil change alarm.
• Program selection from "0" to "9"; increases/decreases the value of each
function in the program.
• Programming button: makes it possible to enter programming of the individual
functions.
• Functions selection key: selects the function to be programmed.
• Key for activating vacuum inside outside containers and/or channelled bags
and/or PUMP FUNCTION ON: activates/deactivates the external evacuation
system of containers and/or channelled bags and/or PUMP FUNCTION ON..
• Stop button: stops the work cycle.
6
6
PUMP
SEL
STOP
3
3
7
7
8
8
2