3. Ceiling Fan Assembly
3.7
Loosen the two Set Screws in the Motor Coupler for
installation of the Downrod (Figure 7).
Seat the downrod in the Motor Coupler (Figure 7).
Rotate and align the Downrod Holes with all the Holes
in the Motor Coupler (Figure 7).
3.8
Align the Clevis Pin Holes in the Downrod with the
Holes in the Motor Coupler.
Install the Clevis Pin and secure with the Hairpin Clip
(Figure 8).
The Clevis Pin must go through the Holes in the Motor
Coupler. It is critical that the Clevis Pin in the Motor
Coupler is properly installed and securely tightened.
Retighten the Phillips Head Set Screws to secure the
Downrod to the Motor (Figure 8).
WARNING
!
It is critical that the clevis pin and set screws in the
motor coupler are properly installed and securely
tightened. Failure to verify that the pin and set screws
are properly installed could result in the fan falling.
3.9
Make sure the Grommet is properly installed in the
Coupler Cover, then slide the Coupler Cover on the
Downrod until it rests on the Fan Motor Housing
(Figure 9).
(Continued)
LOOSEN
PHILLIPS HEAD
LOOSEN PHILLIPS HEAD
SETSCREWS (2)
SET SCREWS (2)
Figure 7
HAIRPIN
CLIP
CLEVIS
PIN
CLEVIS
PIN
RETIGHTEN
RETIGHTEN
PHILLIPS HEAD
PHILLIPS HEAD
SET SCREWS (2)
SETSCREWS (2)
Figure 8
FAN MOTOR
HOUSING
Figure 9
7
4.5"
DOWNROD
MOTOR
MOTOR
COUPLING
COUPLER
MOTOR
MOTOR
COUPLER
COUPLING
HAIRPIN
CLIP
DOWNROD
GROMMET
COUPLER
COUPLING
COVER
COVER
luminancebrands.com
Please contact 1-800-777-4440 for further assistance