Technical Features; Supply Voltage; Connections And Fuses Description - Roger Technology AG/CTRL AGILIK Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 80
3

Technical features

SUPPLY VOLTAGE:

MAXIMUM POWER ABSORBED BY THE NETWORK 270W
NUMBER OF MOTORS THAT CAN BE CONNECTED 1
MOTOR POWER SUPPLY
TYPE OF MOTOR
TYPE OF MOTOR CONTROL
MAXIMUM MOTOR POWER
MAXIMUM EXTERNAL FLASHING LIGHT RATING 5W 24Vdc (model R92/LED24 ROGER)
MAXIMUM BARRIER LIGHTS rating
MAXIMUM ELECTRIC LOCKING SYSTEM RATING 10W 12Vdc
MAXIMUM LIGHT SIGNALLING RATING
ACCESSORIES POWER OUTPUT
OPERATING TEMPERATURE
PROTECTION RATING
PRODUCT SIZE
4

Connections and fuses description

Figure 1 shows the position of the board inside the
unit, the power supply connection and the fuses.
The supply terminal is provided with a 5x20mm
delayed-action fuse of 1A 250V (T1A), F4, that
protects the main circuit of the transformer.
The board is equipped with 3 automotive-type
blade fuses (ATO257):
F1 10A, for the protection of the power circuit
F2 4A, for the protection of the electric locking
system
F3 3A, for the protection of the control logic and of
the peripheral devices
Figures 2,3 and 4 indicate the connections of the
inputs and of the outputs. The description of each
terminal can be found below:
1
BATTERY+, positive terminal of the 24V battery
2
BATTERY-, negative terminal of the 24V battery
3,4
SEC2, secondary circuit of the transformer for
logic and peripheral devices supply (19Vac)
5,6
SEC1, secondary circuit of the transformer for
motor supply (26Vac)
7,8,9 Phases X,Y,Z motor Roger Brushless
10
COM, common terminal for low voltage
inputs and outputs
11
+SC, "open/closed" led (24Vdc, 3W); optional,
to this terminal can also be connected the
supply cable of the photocells TX (only after
setting the parameter
mode) so that the "test photocell" function is
enabled; as an alternative, by connecting both
24
A8  02
, on "extended"
230Vac ± 10% 50Hz
36Vac
sinusoidal brushless (ROGER BRUSHLESS)
"sensored" with field orientation (FOC)
130W
12W 24Vdc
3W 24Vdc
10W 24Vdc
-20°C ... +55°C
IP4X
size in mm. 166x150x48 Weight: 0,254 Kg
TX and RX of the photocells to this terminal
and setting par.
supply, you can obtain the shut-down of the
photocells when the barrier is completely
closed or opened (par.
the photo-test)
12
+LUCI, signalling lights on the bar (+24Vdc),
optional
13
COM, common terminal for low voltage
inputs and outputs
14
+24V, power supply for external devices
maximum 10W
15
+ES,
electric
max.10W
16
+LAM, external flashing light (+24Vdc):
max.5W
17,18 COM, common terminal for low voltage
inputs and output
21
ST, STOP command (contact N.C.)
22
COM, common terminal for low voltage
inputs and output
23
COS, anti-crushing safety edge (NC contact, or
8.2kOhm)
(a)
24
FT, photocell (NC contact)
25
COM, common terminal for low voltage
inputs and output
26
ANT, antenna pole for plug-in radio receiver
(if using an external antenna, connect it with
the RG58 cable)
27
Receiver antenna braid
28
COM, common terminal for low voltage
inputs and output
29
PED, input of the pedestrian opening
command (contact N.A.)
A8  03
04
or
with battery
A8  04
also enables
locking
system
(+12Vdc):
(a)
(a)

Publicidad

Tabla de contenido
loading

Tabla de contenido