A8 00
Open barrier light / +SC output operating mode
00
if the barrier is closed, the light is off; otherwise it is on
slow blinking during opening, fast blinking during closing, standing still light if completely
01
opened, turns off for two times after every 15 seconds if the barrier stops in an intermediate
position
02
the output +SC is used to supply the photocells and performs a test on them
the output +SC in battery mode does not supply the external charges when the barrier is
03
completely opened or completely closed; if supply voltage is present, the output +SC always
provides power
04
the same as for value 03, plus the photo-test function
11 10
Duration of the incoming deceleration when the barrier is completely opened
12 10
Duration of the incoming deceleration when the barrier is completely closed
01
10
01 quick deceleration ... 10 slow deceleration
-
A-
NOTE: parameters
01
A low value (
) implies a quick deceleration, just before reaching the limit stroke, a high value (
triggers the start of the deceleration in advance. By choosing a high value, the maximum speed of the
barrier may be limited.
These parameters can be changed even if the stroke has already been set.
NOTE: the available values can be limited by choosing the par.
15 60
Pedestrian stroke length
01
99
PERCENTAGE of the total stroke
-
21 30
Pause time for automatic closing
00
90
SECONDS
-
92
99
from 2 to 9 MINUTES
-
2-
NOTE: parameter
When one of the photocells is engaged, the timer will be reset and the counter restarts once the photocell
is disengaged.
29 00
Enabling the electric locking system
00
DISABLED
01
ENABLED
The output is enabled for a fixed period of time (2").
31 09
Adjustment of the anti-crushing
01
09
01 = low intervention time ... 09 = high intervention time
-
10
disabled
e-
NOTE: parameter
The intervention of the anti-crushing safety device is enabled during the entire closing process, and
immediately reverses the movement, bringing the barrier in complete open position, exactly as if the safety
edge would have interfered. During the opening process, it reverses the movement only if it occurs in the
first 60 ° of movement.
The ability to perform an automatic closing is then determined by the selection of par.
d-
and
in standard configuration
in standard mode.
in standard mode.
A1
.
10
49
(max 3 attempts).
33
)